Match the curtain to the doorway
The width of the opening is the figure that matters: the curtain should be at least as wide as the door, so no gap is left at the sides. As a rough guide, a 90 centimetre unit suits a single door and a 120 or 150 centimetre unit a wider entrance or double doors, with units side by side for anything wider. The air also has to reach the floor, so a taller doorway needs a more powerful curtain.
Electric heat or a heat pump coil
Electric models warm the air stream with heating elements, so they are simple to fit and need only a power supply. Models with a DX (direct expansion) coil take their heat from an outdoor heat pump unit instead, typically giving around three units of heat for each unit of electricity, so they cost much less to run where a door stands open all day. Their heat outputs run from about 6 to 24 kW (kilowatts), and a larger, busier doorway needs more.
Fitting it above the door
Mount the curtain inside, as close to the top of the opening as possible and across its full width. Electric models with larger heaters need a dedicated circuit fitted by a qualified electrician, and a coil model needs refrigerant pipework to its outdoor unit connected by an F-Gas registered installer. Running costs depend mostly on how long it heats, so turn the heat down in mild weather, and vacuum the air intake regularly so dust does not choke the airflow.